Automatic extinguisher control panel
|
VEKTOR-1 automatic extinguisher control panel
Functions: - Designing of addressable fire alarm system with conventional detectors and manual call points based on VEKTOR-1 automatic extinguisher control panel - Designing of multilevel (hierarchical) system of control panels - Arrangement of central and stand-alone protection of various premises against fires, control of extinguishers, smoke extract, fan and other automatic systems. Complies with EN54-2 , EN54-4, EN54-21, EN54-13. FEATURES:
- central processor radial interface with each unit being potential free that ensures stable operation even with a faulty unit; - integrated 2-zone fire extinguishing control console; - compartment for mounting of up to 20 relays on DIN rail; - communications units and interface collectors for interconnection and work with computer; - free binding of outputs to loop/output statuses (events) with logical formulas without use of auxiliary devices and software; - low current consumption due to usage of fire loops with terminal capacitor and dynamic powering of logical loops; - user-friendly menu (not more complicated than mobile phone); - standard phone keypad; - easy-to-read graphical display (large highlighted characters); - provides many flexible choices from basic conventional (non-addressable) to advanced hard-wire addressable panel/systems, - high reliability and easy maintenance; - transmission of alarm notifications by GSM-communicator.
- fire mode with reverification (without reverification) and terminal capacitor; - fire mode with reverification (without reverification) and terminal resistor; - logical mode (discrete output); - protection mode; - output mode.
- each fire output provides controlling of connection lines; - activation of fire output by event in a loop with automatic fire detectors; - activation of fire output by event in a loop with manual call points; - possibility of extinction process control using manual call points "Manual release mode", "Extinguishant hold off" etc.; - standalone operation and programming of each output; - cascade operation of maximum eight outputs; - operation of outputs in redundant circuits.
- automatic detector output; - manual call point output; - output for connection of the call point "Manual release mode"; - output for connection of the manual call point "Extinguishant hold off"; - output for connection of the manual call point "Release hold off"; - output for connection of the manual call point "Emergency release"; - output for connection of the manual call point "Emergency stop"; - programming of delay time; - programming of extinguishant release time. Parameters of compatibility: - output/loop voltage: 20-30 V for 24V power supply 9.5-15 V for 12V power supply - loop current: 30 mA max - switch current of output of each I/O channel: 50 mA max - switch current of outputs with full load monitoring for connection of sounders: 200 mA max - switch current of outputs for extinguishant monitoring: 4 A max Invariable settings: - sound signal resumes when a new event occurs; - disablement period for fire detectors during fire alarm loop resetting: 4-6 sec. - delay period for fire alarm loop processing after applying power (incl. during reset) to fire detectors: 4-6 sec. - period to automatic resetting of initial fire alarm status (Attention): 5-6 min. ยท |
|