Àðòîí - ëó÷øèå ïîæàðíûå èçâåùàòåëè è îõðàííûå èçâåùàòåëè
HomeSitemapEmail
Ëó÷øèå ïîæàðíûå èçâåùàòåëè
Select a product

About us
News Archives
Products
FAQ
Certificates of Ukraine
Certificates of Russian federation
Distributors Wanted



ARTON-04P

Fire control panels


ARTON-04P


The control panel “ARTON-04P” is designed for the arrangement of centralized and autonomous protection of various objects against fire by the 24-hours control of the status up to 4 fire alarm loops.

The control panel “ARTON-04P” conforms to all the norms of DSTU EN54-2:2003 and DBN V 2.5-13-98.

The control panel “ARTON-04P” controls and reflects with optical indicators alarm statuses (alarm loops): the standby mode, the verification of an alarm loop (if AL is with verification), “Fire”, “Short-circuit”, “Open-circuit”, “AL switched-off”.

The device controls and reflects with optical indictors the following kinds of faults and statuses:

  • The short-circuit of output switches;
  • The open-circuit of output switches’ loads “Light/Sound”, “Fire” and “Fault”;
  • The absence of power voltage of output switches and AL;
  • The absence of A.C. mains 220 V;
  • The critical discharge or the absence of a storage battery;
  • The fault of a charger;
  • A system error.

The protection against an unsanctioned access inside a case is provided in the device (opening or breaking of the cover). When opening the cover, a tamper button activates and the device passes to the “Alarm” mode.

The device is meant for the connection of 2- and 4-wire alarm loops. The connection both active and passive detectors is possible as well as the combined connection of detectors.

The device provides:

  • Automatic charging of a storage battery and the protection against its improper connection;
  • Protection of all the output switches against the short-circuit with automatic restoration of the initial status after the elimination of the short-circuit;
  • Multilevel access to management functions.

With the help of a built-in keyboard it is possible to programme the following parameters and functions:

  • The survey and determination the type of alarm loop zone (with/without verification);
  • Fixation of the basic current of AL;
  • Setting of consumer rights for the management of AL;
  • Change of consumers’ and an engineer’s passwords;
  • Setting of an operational mode of a light-sound detector;
  • Setting of activation time of a light-sound detector;
  • Setting of a mode and programming of operation logics of additional output switches;
  • Reset to factory settings.

Technical specifications of the control panel “ARTON-04P” look in the passport.



 Back to the list of products



Rambler's Top100  

© Arton, 2008. All right reserved.
© Design and programming — Oleksandr Mandryk.